FUJITSU MHD2032AT User Manual

Page 89

Advertising
background image

Interface

5-18

C141-E050-02EN

Command block registers contain the cylinder, the head, and the sector addresses
of the sector (in the CHS mode) or the logical block address (in the LBA mode)
where the error occurred, and remaining number of sectors of which data was not
transferred.

At command issuance (I/O registers setting contents)

1F7

H

(CM)

0

0

1

0

0

0

0

R

1F6

H

(DH)

×

L

×

DV

Start head No. /LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

Start cylinder No. [MSB] / LBA

Start cylinder No. [LSB] / LBA

Start sector No. / LBA [LSB]

Transfer sector count

xx

R = 0

with Retry

R = 1

without Retry

At command completion (I/O registers contents to be read)

1F7

H

(ST)

Status information

1F6

H

(DH)

×

L

×

DV

End head No. /LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

End cylinder No. [MSB] / LBA

End cylinder No. [LSB] / LBA

End sector No. / LBA [LSB]

00 (*1)

Error information

*1

If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.

(2) READ MULTIPLE (X’C4’)

This command operates similarly to the READ SECTOR(S) command. The
device does not generate an interrupt (assertion of the INTRQ signal) on each
every sector. An interrupt is generateed after the transfer of a block of sectors for
which the number is specified by the SET MULTIPLE MODE command.

Advertising
This manual is related to the following products: