2 data transferring commands from host to device – FUJITSU MHD2032AT User Manual

Page 143

Advertising
background image

Interface

5-72

C141-E050-02EN

sector in multiple-sector reading. If the timing to read the Status register does not meet
above condition, normal data transfer operation is not guaranteed.

When the host new command even if the device requests the data transfer (setting in DRQ
bit), the correct device operation is not guaranteed.

Figure 5.4 Protocol for command abort

5.4.2 Data transferring commands from host to device

The execution of the following commands involves Data transfer from the host to
the drive.

WRITE SECTOR(S)

WRITE LONG

WRITE BUFFER

WRITE VERIFY

SECURITY DISABLE PASSWORD

SECURITY ERASE UNIT

SECURITY SET PASSWORD

SECURITY UNCLOK

The execution of these commands includes the transfer one or more sectors of data
from the host to the device. In the WRITE LONG command, 516 bytes are
transferred. Following shows the protocol outline.

a)

The host writes any required parameters to the Features, Sector Count, Sector
Number, Cylinder, and Device/Head registers.

Advertising