Bit 7:

If this bit is 1, it indicates that the automatic off-line data
collection function is enabled.

Status Byte

Meaning

0

Off-line data collection is not started.

2

Off-line data collection has been completed normally.

3

Off-line data collection is in progress.

4

Off-line data collection has been suspended by a command
interrupt.

5

Off-line data collection has been aborted by a command
interrupt.

6

Off-line data collection has been aborted by a fatal error.

Number of off-line data collection segments

Indicates the number of segments required to terminate off-line data
collection.

Time required for next segment [sec]

Indicates the time required to terminate the next segment.

Current segment pointer

Indicates the number of the next segment to be executed.

Off-line data collection capability

Indicates the method of off-line data collection carried out by the drive. If the
off-line data collection capability is 0, it indicates that off-line data collection
is not supported.

Bit

Meaning

0

Indicates that Execute Off-Line Immediate is supported.

1

Vendor unique

2

Indicates that off-line data collection being executed is
aborted when a new command is received.

Failure prediction capability flag

Bit 0: The attribute value data is saved to a media before the device enters

power saving mode.

Bit 1: The device automatically saves the attribute value data to a media

after the previously set operation.

Bits 2 to 15: Reserved bits