4 environmental specifications – FUJITSU MHE2064AT User Manual

Page 29

Advertising
background image

Device Overview

1-8

C141-E057-01EN

(5) Power on/off sequence

The voltage detector circuits (the MHE Series and MHF Series) monitor +5 V.
The circuits do not allow a write signal if either voltage is abnormal. These
prevent data from being destroyed and eliminates the need to be concerned with
the power on/off sequence.

1.4 Environmental Specifications

Table 1.6 lists the environmental specifications.

Table 1.6 Environmental specifications

Item

Specification

Temperature

• Operating

• Non-operating

• Thermal Gradient

5°C to 55°C (ambient)

5°C to 60°C (disk enclosure surface)

–40°C to 65°C

20°C/h or less

Humidity

• Operating

• Non-operating

• Maximum Wet Bulb

8% to 90% RH (Non-condensing)

5% to 95% RH (Non-condensing)

29°C

Altitude (relative to sea level)

• Operating

• Non-operating

–300 to 3,000 m

–300 to 12,000 m