1m1a-1, Height in, Volume (without b umper) cu in. force lbs x 100 – Firestone EMDG198 User Manual

Page 35

Advertising
background image

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly @ 100

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

3.0

14

118

235

356

475

593

Dynamic Characteristics at 3.0 in. Design Height

(Required for Airmount isolator design only)

Volume @ 100 PSIG = 14 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

235

191

199.52

3.33

60

356

274

169.93

2.83

80

475

352

161.74

2.70

100

593

458

165.29

2.75

Description

Assembly Order No.

Blind nut, 1/8 NPT,

WO2-358-3003

brass stud

Assembly weight ........................................................ 0.5 lbs.

Force to collapse to minimum height (@ 0 PSIG) ......... 20 lbs.

Natural

Frequency

CPM

HZ

12

10

8

6

4

2

0

24

20

16

12

8

4

0

4

MAX. HT.

MIN. HT.

3

2

1.5

Volume
100 Psig

20 Psig

40 Psig

60 Psig

120 Psig

100
Psig

80 Psig

Do not use
Airstroke
in shaded
area without
consulting
Firestone

2.5

3.5

CONSULT FIRESTONE

BEFORE USING AS

AIRMOUNT

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

3.0 INCHES

Static Data

B3940

HEIGHT IN.

1M1A-1

35

3.4 MAX O.D.

AT 60 PSIG

HEIGHT

5/16-18
THREADED HOLE
(3/8 DEEP)

5/8-11

1.00

2.40 DIA.

1/8 NPT

AIR INLET

2.88 DIA.

3-5 TURNS

30-50 IN. LBS.

TORQUE

100-130 IN. LBS.

TORQUE

See page 12 for instructions on how to use chart.

NOTE: The dotted line on the static data chart shows
the force capabilities of the 1M1A-1 when attaching an
additional 0.5 inch pedestal, provided by the customer,
to the base of the air spring. If an additional pedestal is
not used, the air spring will behave as the solid line
depicts. Without a pedestal the rubber part will contact
the ground at the height of 2.1 inches and could cause
the rubber part to wear prematurely.

V

OLUME (WITHOUT B

UMPER) CU IN.

FORCE LBS x 100

Style

1M1A-1

Two

Ply

Bellows

Advertising