Height in – Firestone EMDG198 User Manual

Page 41

Advertising
background image

41

MAX. HT.

MIN. HT.

3

2

1

6

5

4

3

2

120 Psig

100 Psig

80 Psig

40 Psig

20 Psig

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

60 Psig

Do not use Airstroke in
shaded area without
consulting Firestone

Volume
100 Psig

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

4.5 INCHES

Static Data

9258

HEIGHT IN.

110

HEIGHT

8.3 MAX O.D.

AT 100 PSIG

4.50 DIA.

3/8-16 BLIND NUTS

(5/8 DEEP)

1.75

1/4 NPT

AIR INLET

15-20 FT. LBS.

TORQUE

NOTE: A bead plate part is shown. This part is
also available with bead rings. Bolts are not included.
See pages 8-10 for explanation.

See page 12 for instructions on how to use chart.

V

OLUME (WITHOUT B

UMPER) CU IN. x 10

FORCE LBS x 1000

Dynamic Characteristics at 4.5 in. Design Height

(Required for Airmount isolator design only)

Volume @ 100 PSIG = 128 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

650

554

173

2.88

60

1,010

795

167

2.77

80

1,390

1,046

162

2.71

100

1,790

1,294

160

2.66

Natural

Frequency

CPM

HZ

Description

Assembly Order No.

Blind nuts, 1/4 NPT

WO1-358-7451

Blind nuts, 3/4 NPT

WO1-358-7484

Socket head aluminum bead
rings (bolts, nuts, washers not
included-use 1/4 cap screws)

WO1-358-0112

Rubber bellows only

WO1-358-0100

Assembly weight ........................................................ 3.0 lbs.

Force to collapse to minimum height (@ 0 PSIG)......... 8 lbs.

Style

110

Two

Ply

Bellows

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly @ 100

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

4.0

117

390

810

1,240 1,700 2,160

3.0

91

490

1,010 1,540 2,090 2,650

Advertising