Height in, Volume (without b umper) cu in. force lbs x 100 – Firestone EMDG198 User Manual

Page 39

Advertising
background image

39

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly @ 100

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

3.3

29.0

130

270

410

590

780

3.0

26.2

200

400

600

800

1,000

2.5

20.0

270

530

800

1,070 1,330

2.0

12.5

320

640

960

1,280 1,600

1.8

10.0

340

670

1,010 1,350 1,680

Description

Assembly Order No.

Blind nuts, 1/4 NPT

WO2-358-5000

Stainless steel plates

WO2-358-5002

Assembly weight ...................................................... 1.25 lbs.

Force to collapse to minimum height (@ 0 PSIG)...... 8.0 lbs.

4.0 3.5 3.0 2.5 2.0 1

MAX. HT.

MIN. HT.

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

0

Volume
100 Psig

Do not use
Airstroke in
shaded area
without
consulting
Firestone

40 Psig

20 Psig

80 Psig

100 Psig

120 Psig

60 Psig

1.8

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

3.0 INCHES

Static Data

B4165

HEIGHT IN.

16-ST

5.38 MAX OD

HEIGHT

1.75

4.44 DIA

1/4 NPT

3/8-16 UNC

15-20 FT. LBS.

TORQUE

NOTE: The bellows extends beyond the bead plates at
minimum height.

See page 12 for instructions on how to use chart.

V

OLUME (WITHOUT B

UMPER) CU IN.

FORCE LBS x 100

Style

16-ST

Two

Ply

Bellows

Dynamic Characteristics at 3.0 in. Design Height

(Required for Airmount isolator design only)

Volume @ 100 PSIG = 26.2 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

400

704

249

4.2

60

600

1,003

243

4.1

80

800

1,303

240

4.0

100

1,000

1,602

238

4.0

Natural

Frequency

CPM

HZ

Advertising