Height in – Firestone EMDG198 User Manual

Page 52

Advertising
background image

Dynamic Characteristics at 5.0 in. Design Height

(Required for Airmount isolator design only)

Volume @ 100 PSIG = 1,315 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

11,030

6,237

141

2.35

60

16,710

8,763

136

2.26

80

22,460

11,345

133

2.22

100

28,290

13,751

131

2.18

Natural

Frequency

CPM

HZ

7

6 5 4 3 2

MAX. HT.

MIN. HT.

30

25

20

15

10

5

100 Psig

80 Psig

20 Psig

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

60 Psig

Volume
100 Psig

40 Psig

Do not use Airstroke in
shaded area without
consulting Firestone

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

5.0 INCHES

Static Data

8701

HEIGHT IN.

126

52

HEIGHT

20.36 DIA.

24 (3/8-24) BOLTS

EACH RING

28-32 FT. LBS.

TORQUE

19.00 BOLT CIRCLE DIA.

22.4 MAX O.D.

AT 100 PSIG

NOTE: A bead ring part is shown. This part is also avail-
able with rolled plates. See page 11 for explanation.

See page 12 for instructions on how to use chart.

V

OLUME (WITHOUT B

UMPER) CU IN. x 100

FORCE LBS x 1000

Description

Assembly Order No.

Ribbed neck aluminum
bead rings (equal spacing),
1

7

/

8

bolts, nuts, washers

WO1-358-7727

Rolled Plate Assembly,
1/2 blind nuts, 3/4 NPT

WO1-358-7726

Assembly weight ...................................................... 21.3 lbs.

Force to collapse to minimum height (@ 0 PSIG)....... 25 lbs.

Style

126

Two

Ply

Bellows

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly @ 100

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

6.0

1,589 4,390 8,880 13,580 18,360 23,450

5.0

1,315 5,560 11,030 16,710 22,460 28,290

4.0

1,007 6,120 12,120 18,330 24,660 30,930

3.0

676

6,440 12,830 19,330 25,990 32,600

Advertising