Height in – Firestone EMDG198 User Manual

Page 57

Advertising
background image

57

9 8 7 6 5 4

MAX. HT.

MIN. HT.

3

2

1

2

1

2.8

40 Psig

20 Psig

Volume
100 Psig

80 Psig

100 Psig

120 Psig

Do not use Airstroke in
shaded area without
consulting Firestone

60 Psig

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

6.5 INCHES

Static Data

8829

HEIGHT IN.

224

HEIGHT

3/8-16 BLIND NUTS

(5/8 DEEP)

8.0 MAX O.D.

AT 100 PSIG

2.75

5.31 DIA.

1/4 NPT

AIR INLET

15-20 FT. LBS.

TORQUE

NOTE: A bead plate part is shown. This part is also avail-
able with bead rings. See pages 8-10 for explanation.

See page 12 for instructions on how to use chart.

V

OLUME (WITHOUT B

UMPER) CU IN. x 100

FORCE LBS x 1000

Dynamic Characteristics at 6.5 in. Design Height

(Required for Airmount isolator design only)

Volume @ 100 PSIG = 171 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

730

361

132

2.20

60

1,130

523

128

2.13

80

1,530

690

126

2.10

100

1,940

849

124

2.07

Natural

Frequency

CPM

HZ

Description

Assembly Order No.

Blind nuts, 1/4 NPT

WO1-358-3400

Blind nuts, 3/4 NPT

WO1-358-3403

Assembly weight ........................................................ 5.0 lbs.

Force to collapse to minimum height (@ 0 PSIG)....... 14 lbs.

Style

224

Two

Ply

Bellows

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly @ 100

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

7.0

181

320

630

990

1,340 1,710

6.0

160

400

820

1,260 1,700 2,160

5.0

134

470

960

1,490 2,040 2,570

4.0

105

550

1,110 1,720 2,310 2,930

3.0

73

590

1,210 1,860 2,480 3,150

Advertising