Height in – Firestone EMDG198 User Manual

Page 83

Advertising
background image

Dynamic Characteristics at 8.0 in. Design Height

(Required for Airmount isolator design only)

Volume @ 80 PSIG = 58 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

280

62

88

1.47

60

440

89

84

1.40

80

600

116

83

1.38

100

810

107

68

1.13

Description

Assembly Order No.

Blind nut, 1/8 NPT

WO2-358-7010

Assembly weight ........................................................ 1.6 lbs.

Natural

Frequency

CPM

HZ

9 8 7 6 5

MAX. HT.

9

8

7

6

5

4

3

2

1

0

60 Psig

20 Psig

100 Psig

80 Psig

40 Psig

Volume
80 Psig

Do not use Airstroke in
shaded area without
consulting Firestone

1 2 1 1 1 0

9

8

7

6

5

4

3

2

1

0

MIN. HT.

5.75

CONSULT FIRESTONE

BEFORE USING AS

AIRMOUNT

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

8.0 INCHES

Static Data

8612

HEIGHT IN.

HEIGHT

4.0 MAX O.D.

AT 80 PSIG

12-18 FT. LBS.

TORQUE

1/2-13 THREADED HOLE

(.80 DEEP)

2.76 DIA.

1/8 NPT

AIR INLET

2.13 DIA.

25-30 FT. LBS.

TORQUE

.62

3/4-16

NOTE: Bellows will not compress properly with less
than 10 PSIG internal pressure.

See page 12 for instructions on how to use chart.

V

OLUME (WITHOUT B

UMPER) CU IN. x 10

FORCE LBS x 100

Style
7010

Two

Ply

Bellows

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly

@ 80

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

10.0

75

150

310

480

650

880

9.0

67

140

300

470

630

870

8.0

58

140

280

440

600

810

7.0

50

130

270

430

580

740

83

7010