1.3.3 Adjusting the Pilot Flame

1. On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, use a flat-

tipped screwdriver to turn the pilot adjustment screw counterclockwise to increase the length of the

flame or clockwise to decrease the length of the flame. (Use the diagram on the previous page to

locate this screw.) Adjust the flame to a length of 1- to 1½- inches (25 to 38 mm).

2. On non-CE valves, reinstall the pilot adjustment screw cap.

1.3.4 Adjusting Burner Ceramic Target Spacing and Alignment

Proper spacing of the top edge of the ceramic targets is ¾-inch (13 mm) from the frypot side. To adjust

target spacing, bend the brackets away or toward the frypot, as needed. A length of board ¾-inch thick is

useful as a gauge to verify spacing and alignment.

1.3.5 Calibrating the Thermostat

Fryers with thermostat access doors:

1. Fill the frypot to the lower OIL-LEVEL line with cooking oil. If using solid shortening, pack it

tightly into the frypot before starting the calibration procedure.

2. Light the pilot. (See Chapter 3 of the Installation and Operation manual for detailed lighting

instructions.)

3. Insert a thermometer or pyrometer into the frypot, about 1-inch from the thermostat.

4. Open the thermostat access door and set the thermostat on the fryer to 325°F (162°C).

5. When oil reaches 325°F (162°C), allow the burners to cycle on and off three times.

6. Take a temperature reading when the burners go off for the third time.

7. Loosen the setscrews in the thermostat knob and turn the knob to the temperature established by the

thermometer/pyrometer reading.

There should be approximately ¾-inch spacing between the top edge