8. Allow the burners to cycle on and off three more times and recheck the thermometer/pyrometer reading

against the thermostat setting. Temperature readings should be within 5°F (2.8°C) of setpoint.

Fryers with thermostat control panels:

NOTE: Remove the thermostat knob from its shaft to allow the control panel to hinge downward.

Follow the instructions in Section 1.4.2 to remove the knob and control panel.

1. Fill the frypot to the lower OIL-LEVEL line with cooking oil. If using solid shortening, pre-melt it

before starting the calibration procedure.

2. Ensure the fryer power switch is in the OFF position, and light the pilot. (Refer to Chapter 3 of the

Installation and Operation manual for detailed lighting instructions.)

3. Insert a thermometer or pyrometer into the frypot so that it

touches the thermostat guard.

4. Loosen the setscrew and stop screw securing the thermostat

shaft extension to the flexible shaft. Remove the extension to

expose the slot in the end of the flexible shaft.

5. Place the fryer power switch in the ON position.

NOTE: If the burner does not light at this time, it does not

mean the thermostat is defective.

Use a small flat-head screwdriver to slowly turn the flexible shaft counterclockwise until the burner

lights.

6. When the oil temperature reaches 325°F (162°C), slowly turn the flexible shaft clockwise until the

burner turns off. Then, allow the fryer to sit for a few minutes.

7. Repeat Steps 5 and 6 at least three times to ensure that the setting is accurate. The thermostat control

is considered properly calibrated if the burner lights when the cooking oil cools to 325°F (162°C).
Do not take the reading when the burner shuts off after raising the temperature.

8. Once the thermostat is calibrated, allow the burner to cycle on and off at least three times to ensure

that it lights at the correct temperature.

9. After the calibration is complete, place the fryer power switch in the OFF position and disconnect

the fryer from the electrical supply.

10. Carefully replace the thermostat shaft extension so that the stop screw points straight up. Without

rotating the flexible shaft, tighten the stop screw, locking nut, and setscrew.

11. Close the fryer control panel and replace the screws and bezel.

12. Reinstall the thermostat knob. Align its pointer with the 325°F (162°C) index mark on the temperature

dial.

13. Reconnect the fryer to the electrical supply.

CAUTION

The thermostat flexible shaft

must not be rotated while

installing the thermostat

shaft extension!

Do not rotate the flexible shaft

more than two turns in either

direction. Doing so will cause

damage to the thermostat.