5 gas connections (cont.), 5 gas specifications, Australian requirements – Frymaster DEAN FPD65 User Manual

Page 19: Non-ce (altitudes of 2000 feet or less)

Advertising
background image

HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3-6

3.5 Gas Connections (cont.)

WARNING

Do not attach accessories to this fryer unless fryer is secured from tipping. Personal

injury may result.

2. The fryer must be restrained by means independent of the flexible coupling or

connector in order to limit the movement of the fryer. Restraining brackets are
located on the back panel of the fryer for the attachment of restraints.

3. If disconnection of the restraint is necessary, this restraint must be reconnected after

the fryer has been returned to its originally installed position.

I. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.

AUSTRALIAN REQUIREMENTS

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other
relevant statutory regulations.

3.5 Gas Specifications

NON-CE (Altitudes of 2000 feet or less)

EQUIPMENT

PRESSURE

MODEL

INPUT

(BTU)

GAS

TYPE

ORIFICE

(MM)

ORIFICE

PART NO.

QTY

MBAR INCH

W.C.

D20G 50

NAT

LP

2.18(#44)
1.40(#54)

810-2050
810-2324

2
2

10

27.5

4

11

D50G 85

NAT

LP

2.08(#45)
1.32(#55)

14-0067-45

810-2441

4
4

10

27.5

4

11

D50G(HP) 120

NAT

LP

2.53(#39)
1.51(#53)

810-2048
810-2059

4
4

10

27.5

4

11

D50GDDHP 115

NAT

LP

2.44(#41)
1.51(#53)

14-0067-41

810-2059

4
4

10

27.5

4

11

D60G 112

NAT

LP

2.08(#45)
1.32(#55)

14-0067-45

810-2441

5
5

10

27.5

4

11

D60G(HP) 150

NAT

LP

2.53(#39)
1.51(#53)

810-2048
810-2059

5
5

10

27.5

4

11

D80G 122

NAT

LP

2.26(#43)
1.40(#54)

810-2049
810-2324

5
5

10

27.5

4

11

D80G(HP) 165

NAT

LP

2.58(#38)
1.61(#52)

810-2062
810-2063

5
5

10

27.5

4

11

HD50G 95

NAT

LP

2.26(#43)
1.40(#54)

810-2938
810-2939

4
4

10

27.5

4

10

HD60G 125

NAT

LP

2.26(#43)
1.40(#54)

810-2938
810-2939

5
5

10

27.5

4

10

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.
(Pilot Flame Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-volume is achieved.)

Advertising