HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS

CHAPTER 5: CONTROLLER OPERATING INSTRUCTIONS

5–2

5.1 Operating Instructions: Electronic Thermostat Controller (cont.)


FRYER POWER SWITCH – This switch turns the fryer on and off. When the power switch is in
the "ON" position, the indicator light will be lit when calling for heat.

BOIL-OUT SWITCH
(Optional) – When the boil-out switch is "ON", it will bypass the electronic
thermostat melt-cycle, and allow the water temperature to reach approximately 196°F (91°C).

DRAIN RESET SWITCH
(Optional) – Resets drain safety switch after draining the fryer. Drain
valve must be closed completely before resetting switch.

MANUAL FILTER POWER SWITCH
(if equipped with filter system) – Controls power to the
filter pump in the event the primary system fails. Fryer Power Switch should be in "OFF" position
when in use.

FILTER RESET BREAKER
(7 Amp Circuit Breaker- 120VAC or 5 Amp Circuit Breaker-
230VAC) – the breaker is inline between the filter switch and the pump. Ensure filter power is off
prior to resetting or replacing.

5 AMP (115VAC) or 2 AMP (230VAC) FUSE
– each fryer circuit is protected by a 5 amp
(115VAC) or 2 amp (230VAC) fuse located under the control panel.

5.2 Electronic Thermostat Controller/Computer















POWER

BOIL OUT

F

F

N

F

BOIL OUT

F

O

F

O

N

F

F

O

F

POWER

O

O

O

M

K

N

O

N

MAIN POWER

U

P

T

O

ON OFF ON

A

C

B

T

Fryer Power Switch: controls power to
each individual fryer, both in Electronic
Thermostat or back-up mode.

Boil-Out Switch: operates only in "Electronic Thermostat" mode.
When "ON", this switch bypasses the Electronic Thermostat
melt-cycle and allows the water temperature to reach 196°F
(91°C).

Main Power Switch (optional): connects/disconnects primary
power; double-lighted with center position "OFF". This switch
controls two Electronic Thermostat controllers/Compu-Fry or
remote computers and/or two back-up thermostats (optional).

High-Limit Reset Switch: located under
each individual control panel. This
switch must be manually reset if fryer
exceeds high-limit setpoint.

Filter Reset Switch [7 Amp (115VAC) or
5 Amp (230VAC) Circuit Breaker]: this
switch is inline between the filter pump
and incoming line voltage. Ensure
power is "OFF" before resetting or
replacing.