2 boil-out procedure (cont.) – Frymaster DEAN FPD65 User Manual

Page 25

Advertising
background image

HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS

CHAPTER 4: FRYER OPERATIONS

4-4

4.2 Boil-Out Procedure (cont.)

A. Pour cleaning solution into the frypot and add water to the bottom OIL LEVEL line scribed

in the back of the frypot.

B. Operating thermostat-equipped fryers: Set dial/temperature controller to 225°F (107ºC), just

above that of boiling water.

C. Filtration/Boil-Mode equipped fryers: Turn fryer power switch to "ON". Press the fryer-

reset switch (if applicable). Turn the boil-out switch "ON".

CAUTION

If the pilot and main burner go out, the fryer(s) MUST be left completely shut down at

least 5 minutes before lighting.


D. The main burner will ignite.

E. When the solution nears boiling point, reset the temperature controller to 200° (93ºC).

F. The burners should shut off just as the water starts to boil.

CAUTION

Do not leave fryer unattended. The boil-out solution may foam and overflow if fryer is

left unattended. Press ON/OFF switch to the "OFF" position (Filtration/Boil-Mode

equipped fryers) or reduce temperature (Operating Thermostat equipped fryers) to

control this condition.

G. The burners will heat the boil-out solution to a simmer. Simmer the solution for

approximately 45 minutes. Wearing protective gloves, scrub the sides of the frypot and the
tubes with the L-shaped Teflon brush, being careful not to disturb the temperature sensing
probes and the high-limit thermostat.

H. Do not allow the water level to decrease below the bottom OIL LEVEL line in frypot during

boil-out operation.

WARNING

Water or boil-out solution

MUST not be allowed to drain into the filter pan or filter

system. Irreversible damage will result if water is allowed into the system.

I.

Operating Thermostat equipped fryers: After boil out is complete, turn the thermostat dial to
"OFF". Filtration/Boil-Mode equipped fryers: After boil out is complete, turn the boil-out
and fryer switches to "OFF". Drain the solution from the frypot. Place a metal stockpot of
sufficient size to safely hold the entire contents of the frypot under the drain port to collect
the water/boil-out solution. Do not allow water or boil-out solution to drain into the filter
pan. The filter pump is not designed for water operation, and will be irreparably damaged
(see warning statement above).

Advertising
This manual is related to the following products: