(10) INITIALIZE DEVICE PARAMETERS (X’91’)

The host system can set the number of sectors per track and the maximum head
number (maximum head number is “number of heads minus 1”) per cylinder with
this command. Upon receipt of this command, the device sets the parameters. Then
the device reports the status to the host system.

When the SC field is specified to X’00’, an ABORTED COMMAND error is
posted. Other than X’00’ is specified, this command terminates normally.

The parameters set by this command are retained even after soft reset issuance or
power save operation regardless of the setting of disabling the reverting to default
setting, however, the COMRESET is not retained.

The operation is always performed in CHS mode, with the command ignoring any
setting of LBA mode.

Error reporting conditions

(1) "00h" is specified in the SC field (ST = 51h, ER = 04h).

(2) A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block Registers setting contents)

CM

1 0 0 1 0 0 0 1

DH

x x x x

Max.

head

No.

CH

CL

SN

SC

FR

xx

xx

xx

Number of sectors/track

xx


At command completion (Shadow Block Registers contents to be read)

ST Status

information

DH

x x x x

Max.

head

No.

CH

CL

SN

SC

ER

xx

xx

xx

Number of sectors/track

Error information