FUJITSU MHT2060BH User Manual

Page 81

Advertising
background image

5.1 Physical Interface

C141-E203-01EN 5-7

Table 5.1 Physical Layer Electrical Requirements (2/2)

Nom

Min

Max

Units

Comments

Rx single-ended
impedance

40

Ohm

As seen by TDR with 100 ps (max) edge
looking into connector (20%-80%).

TDR set to produce simultaneous positive
pulses on both signals of the Rx pair.

C

ACcoupling

12

nF

Coupling capacitance value for AC
coupled TX and RX pairs

TX DC clock
frequency skew

-350

+350

ppm

Specifies the allowed ppm tolerance for
TX DC frequency variations around the
nominal 1.5GHz

TX AC clock
frequency skew

-5000

+0

ppm

Specifies the allowed ppm tolerance for
TX AC frequency variations around the
nominal 1.5GHz

TX differential
skew

20

ps

Nominal value architecture specific

Squelch
detector
threshold

100 50 200

mV

p-p

Minimum differential signal amplitude

COMRESET/C
OMINIT
detector off
threshold

175

525

ns

Detector shall reject all bursts with
spacings outside this spec

COMRESET/C
OMINIT
detector on
threshold

320

304

336

ns

Detector shall detect all bursts with
spacings meeting this period

COMRESET/C
OMINIT
transmit
spacing

320.0

310.4

329.6

ns

Differential crosspoints of last and first

edges of bursts

COMWAKE
detector off
threshold

55

175

ns

Detector shall reject all bursts with
spacings outside this spec

COMWAKE
detector on
threshold

106.7

101.3

112

ns

Detector shall detect all burst spacings
meeting this period

COMWAKE
transmit
spacing

106.7

103.5

109.9

ns

Differential crosspoints from last to first

edges of bursts

UI

OOB

646.67 686.67

ps

Operating data period during OOB burst
transmission

Advertising
This manual is related to the following products: