4 command protocol, 1 non-data command protocol – FUJITSU MHT2060BH User Manual

Page 215

Advertising
background image

5.4 Command Protocol

C141-E203-01EN 5-141

5.4 Command Protocol

The host should confirm that the BSY bit of the Shadow Block Status register of
the device is 0 prior to issue a command. If BSY bit is 1, the host should wait for
issuing a command until BSY bit is cleared to 0.

Commands can be executed only when the DRDY bit of the Status register is 1.
However, the following commands can be executed even if DRDY bit is 0.

EXECUTE DEVICE DIAGNOSTIC

INITIALIZE DEVICE PARAMETERS

5.4.1 Non-data command protocol

Execution of the following commands does not involve data transfer between the
host and the device.

RECALIBRATE

SEEK

READ VERIFY SECTOR(S) (EXT)

EXECUTE DEVICE DIAGNOSTIC

INITIALIZE DEVICE PARAMETERS

SET FEATURES

SET MULTIPLE MODE

SET MAX ADDRESS (EXT)

READ NATIVE MAX ADDRESS (EXT)

IDLE

IDLE IMMEDIATE

STANDBY

STANDBY IMMEDIATE

CHECK POWER MODE

SMART DISABLE OPERATION

SMART ENABLE/DISABLE AUTOSAVE

SMART ENABLE OPERATION