BID80 SERIES GAS FRYERS

CHAPTER 2: IMPORTANT INFORMATION

2-2

2.4 Pre-Installation (cont.)

2. Frymaster BID80 Series gas fryers require 120VAC 60 cycle or 230VAC single-phase 50-

hertz (International/CE) electrical service and are equipped with a 16-3 SJT grounded
flexible power cord for a direct connection to the power supply. Amperage draw for each
unit depends on the accessories supplied with the unit/system.

B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-

certified for the following installations:

1. Commercial installation only (not for household use).

2. Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable

legs or 5-inch (13-cm) casters;

3. Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches

(15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch
(13-cm) casters.

DANGER

Local building codes usually prohibit a fryer with its open tank of hot oil from being

installed beside an open flame of any type, whether a broiler or the open burner of a

range.

C. Installation Standards:

1. U.S. installations must meet:

2. Canadian installations must meet:

American National Standard Institute

CAN 1-B149 Installation Codes

ANSI Z83.11

Canadian Gas Association

American Gas Association

55 Scarsdale Road

8501 E. Pleasant Valley Road

Don Mills, ONT, M3B 2R3

Cleveland, OH 44131

National Electrical Code

Canadian Electric Code c22.1, part 1

ANSI/NFPA #70

Canadian Standards Association

American National Standard Institute

178 Rexdale Blvd.

1430 Broadway

Rexdale, ONT, M9W 1R3

New York, NY 10018

NFPA Standards #96 and #211
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110