Bid80 series gas fryers chapter 8: troubleshooting – Frymaster BID80 Series User Manual

Page 45

Advertising
background image

BID80 SERIES GAS FRYERS

CHAPTER 8: TROUBLESHOOTING

8-1

8.1 General

DANGER

Hot cooking oil/shortening will cause severe burns. Never attempt to move this

appliance when filled with hot cooking oil/shortening or to transfer hot cooking

oil/shortening from one container to another.

DANGER

This equipment should be unplugged when servicing, except when electrical circuit

tests are required. Use extreme care when performing such tests.

This appliance may have more than one electrical power supply connection point.

Disconnect all power cords before servicing.

Inspection, testing and repair of electrical components should be performed by an

authorized service agent only.

The problems and possible solutions covered are those most commonly encountered.

To troubleshoot, perform the test set-up at the beginning of each condition. Follow each step in
sequence.

8.2 Pilot Burner Malfunction

A. Pilot will not ignite; no evidence of gas at pilot burner.

1. Check that gas valve is open and gas is present at the gas valve.

2. Check pilot burner orifice for dirt or lint.

3. Remove pilot burner gas-supply line and check for contamination; blow out if necessary,

then reinstall.

B. Pilot burner ignites but will not remain lit when gas valve manual knob is released.

1. Check that thermocouple lead is properly screwed into thermocouple connection bushing

on gas valve.

2. Remove end of thermocouple lead from thermocouple connection bushing and clean with

fine sandpaper or emery cloth.

3. Pilot flame may be too high or too low. Adjust pilot flame adjustment screw so that pilot

flame extends about ¾-inch (19-mm) above the top of the pilot burner.

Advertising