1. OPERATION

2

1.2

Power On/Off

Press the

/BRILL key to turn on the power.

The unit beeps, the startup screen appears
and then the last-used display is shown.

To turn off the power, press the

/BRILL

key more than three seconds. The time re-
maining until power off is counted down on
the screen.

1.3

How to Adjust Dis-
play Brilliance and
Panel Dimmer

1. With the equipment powered, press the

/BRILL key momentarily to show the

brilliance adjustment window for the dis-
play and the panel.

2. Press the

/BRILL key to adjust bril-

liance. Continuous pressing changes the
brilliance cyclically.
(0

→1→...→9→8→...→0→1→...). "0" is

the lowest and "9" is the highest.
You can also use W or X for the adjust-
ment.

3. Press the ENTER or MENU/ESC key to

save the setting and close the window.
(The window is automatically closed if the
brilliance is not adjusted within approx.
six seconds.)

Note: When the power is reapplied after turn-
ing off the equipment with minimum brilliance,
minimum brilliance will be set after the equip-
ment goes through its initial start up. (The

start up screen appears with the maximum
brilliance.) Adjust the brilliance as necessary.

1.4

Selecting a Display

The FCV-295 has seven display modes: low
frequency display, high frequency display,
dual frequency display, low frequency+zoom,
high frequency+zoom, user 1 display, and
user 2 display. Select one with the MODE
control as follows:

1. Rotate the MODE control to open the

mode selection window.

2. Rotate the MODE control to select a dis-

play.

1.4.1

Single frequency display

Low frequency

The lower the frequency of the ultrasonic sig-
nal, the wider the detection area. Therefore,
the low frequency is useful for general detec-
tion and judging bottom condition.

High frequency

The higher the frequency of the ultrasonic sig-
nal, the better the resolution. For this reason
the high frequency is ideal for detailed obser-
vation of fish schools.

Program No. 0252365-XX.XX

Dual (LF/HF)

( ): Mode indication at the top of the screen
BL: Bottom Lock

LF: Low Frequency

BZ: Bottom Zoom HF: High Frequency
MZ: Marker Zoom BD: Bottom Discrimination

LOW frequency zoom mode
(BL-LF, BZ-LF, MZ-LF, BD-LF)

Low frequency single mode (LF)

High frequency single mode (HF)

High frequency zoom mode
(BL-HF, BZ-HF, MZ-HF, BD-HF)

User 1, 2