Furuno FCV295 User Manual

Page 22

Advertising
background image

1. OPERATION

14

3. Use S or T to select an alarm and press

the [ENTER] key.

4. Use S or T to select alarm type:

On: Bottom and Fish (B/L) alarms
Defined Area/All Area: Fish (Normal)
alarm
Inside/Outside: Temperature, Speed
and Arrival alarms
Inside: Alarm generated when speed,
water temperature or arrival distance is
within the range set.
Outside: Alarm generated when speed,
water temperature or arrival distance is
outside the range set.

5. Press the [ENTER] key. For "All Area"

Fish (Normal) alarm, go to step 13. For
Arrival alarm, go to step 10.

6. Use S or T to select From.
7. Press the [ENTER] key.

8. Use T to set starting depth, temperature

or speed as appropriate and press the
[ENTER] key. For Bottom and Fish (Nor-
mal), the starting depth is the range from

the transducer, and for Fish (B/L), from
the bottom.

9. Press the [ENTER] key.
10. Use T to select Span (or Radius in case

of Arrival) and press the [ENTER] key.

11. Use S or T to set the range of depth,

temperature, speed or distance as appro-
priate. To shorten the alarm range marker
use S and to lengthen it use T.

12. For the bottom alarm, temperature alarm,

speed alarm or arrival alarm, press the
[ENTER] key to finish, and then go to step
16. For a fish alarm, press the [ENTER]
key and go to step 13.

13. Use S or T to select Fish Level and

press the [ENTER] key.

14. Use S or T to select the echo strength

level which will trigger the fish alarm.
Weak: Light-blue or stronger echoes
Medium: Yellow or stronger echoes
Strong: Red and reddish-brown echoes

15. Press the [ENTER] key.
16. Press the [MENU/ESC] key twice to close

the menu.

Note: To disable an alarm, select Off at step
4 in the above procedure.

Bottom

and

Fish (B/L)

alarms

Fish (Normal)

alarm

Temperature,

Speed and

Arrival alarms

Bottom alarm/

Fish (Normal) alarm

Fish (B/L) alarm

Temperature alarm

Speed alarm

Alarm range marker
- Bottom alarm, Fish alarm (normal): Right
- Fish alarm (B/L): Center

Alarm icon*

Alarm range

Starting
point

Advertising