5-5

The computer displays

REMOVE PAN.

*NOTE: If the filter pad change time has expired, normally every 25 hours,
the

CHANGE FILTER PAD? message repeats every 15 minutes

instead of every four minutes.

6. Remove the pan. The computer display changes to

CHANGE PAD. Change the filter pad and

ensure the filter pan has been pulled forward, out of the cabinet for at least 30 seconds. Once the
pan has been out for 30 seconds the computer displays

OFF. Ensure the pan is dry and

assembled correctly. Push the filter pan back into the fryer. Ensure “

A” is displayed on the MIB

board.

7. Switch the computer on. The computer displays

low temp until the fryer reaches setpoint.


8. If a filtration error occurs six consecutive times, the return valve closes and the computer

displays

SERVICE REQUIRED alternating with YES and an alarm.

9. Press 9 (1

yes) to silence alarm and continue.

The computer displays

SYSTEM ERROR and the error message for 15

seconds changing to

SYSTEM ERROR FIXED alternating with YES

NO.

10. Press 8 (2

NO) to continue cooking. Call your ASA to repair and reset

the fryer. The error will be re-displayed every 15 minutes until the issue
is repaired. Auto filtration and auto top off is disabled until the fryer is
reset.


Advertising