Problem probable causes corrective action – Frymaster BIELA14 User Manual

Page 70

Advertising
background image

7-2

7.2 Troubleshooting

7.2.1 Computer and Heating Problems

Problem

Probable Causes

Corrective Action

A.

Computer not turned on.

A.

Press the ON/OFF switch to turn
the computer on.

B.

No power to the fryer.

B.

Verify computer power cord is
plugged in and that circuit breaker
is not tripped.

C.

Computer has failed.

C.

Call your ASA for assistance.

D. Damaged computer wiring
harness.

D.

Call your ASA for assistance.

No Display on

Computer.

E. Power supply component or

interface board has failed.

E.

Call your ASA for assistance.

M3000 displays

IS

VAT FULL?

YES NO after a

filtration.

A filter error has occurred due to dirty
or clogged filter pad or paper, clogged
filter pumps, improperly installed
filter pan components, worn or
missing O-rings, cold oil or filter
pump thermal overload.

Follow instructions on page 5-4
through 5-6 to clear the filter error.
If problem persists, call your ASA
for assistance.

M3000 displays

CHANGE FILTER

PAD?

Filter error has occurred, filter pad
clogged, 25 hour filter pad change
prompt has occurred or change filter pad
was ignored on a prior prompt.

Change the filter pad and ensure the
filter pan has been removed from the
fryer for a minimum of 30 seconds.
Do

NOT ignore

CHANGE

FILTER PAD prompts.

A.

Main power cord not plugged in.

A.

Verify that both the main power
cord and 120V is fully seated in its
receptacle, locked into place and
that circuit breaker is not tripped

B.

Computer has failed.

B.

Call your ASA for assistance.

Fryer does not heat.

C.

One or more other components have
failed.

C.

Call your ASA for assistance.

Fryer heats until high-

limit trips with heat

indicator ON.

Temperature probe or computer has
failed.

Call your ASA for assistance.

Fryer heats until high-

limit trips without

heat indicator ON.

Contactor or computer has failed

Call your ASA for assistance.


7.2.2 Error Messages and Display Problems

Problem

Probable Causes

Corrective Action

M3000 display is in

wrong temperature

scale (Fahrenheit or

Celsius).

Incorrect display option programmed.

Toggle between F° to C° by pressing
and holding

3and4simultaneously

until

TECH MODE appears. Enter

1658. The computer displays OFF.
Turn the computer on to check
temperature. If the desired scale is not
displayed, repeat.

Advertising