3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.

4. On non-CE fryers only, place the gas valve in the ON position.

5. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for

at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table below. The tables list the burner manifold gas pressures for each of the gas
types that can be used with this equipment.

Gas

Single

Vat

Dual

Vat

Natural Gas Lacq
(G20) under 20 mbar

7

7

Natural Gas Gronique *
(G25) under 25 mbar

10

10

Natural Gas Gronique
(G25) under 20 mbar

10

10

Butane/Propane
(G30) at 28/30 or 50 mbar

17

17

Propane
(G31) under 37 or 50 mbar

20

20

CE Standard

Burner Manifold Gas Pressures

Pressure (mbar)

* Belgian G25 = 7,0 mbar (single or dual)

Gas

Pressure

Natural

3" W.C.

0.73 kPa

Propane

8.25" W.C.

2.5 kPa

Non-CE Standard

Burner Manifold Gas Pressures

6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the

correct pressure.

Non-CE

Valve

CE

Valve

GAS VALVE REGULATOR CAP