Frymaster Enodis MPH52/55 SERIES User Manual

Page 32

Advertising
background image

1-25

1.7

Troubleshooting and Problem Isolation

Because it is not feasible to attempt to include in this manual every conceivable problem or trouble
condition that might be encountered, this section is intended to provide technicians with a general
knowledge of the broad problem categories associated with this equipment, and the probable causes
of each. With this knowledge, the technician should be able to isolate and correct any problem
encountered.

Problems you are likely to encounter can be grouped into six categories:

1. Ignition failure
2. Improper burner function
3. Improper temperature control
4. Computer malfunctions
5. Filtration malfunctions
6. Leakage

The probable causes of each category are discussed in the following sections. A series of
Troubleshooting Guides is also included at the end of the chapter to assist in solving some of the
more common problems.

1.7.1 Ignition

Failure

Ignition failure occurs when the ignition module fails to sense a flame within the 4-second time
delay period and locks out. When this happens, the module sends 24 VAC through the interface
board alarm circuit to the computer.

M2000 computers display “

IGNITION FAILURE

.”


The three primary reasons for ignition failure, listed in order of probability, are problems related to:

1. Gas and/or electrical power supplies

2. Electronic circuits

3. Gas valve.

PROBLEMS RELATED TO THE GAS AND/OR ELECTRICAL POWER SUPPLIES


The main indicators of this are that an entire battery of fryers fails to light and/or there are no
indicator lights illuminated on the fryer experiencing ignition failure. Verify that the quick
disconnect fitting is properly connected, the fryer is plugged in with connector twisted and locked,
the main gas supply valve is open, and the circuit breaker for the fryer electrical supply is not
tripped.

PROBLEMS RELATED TO THE ELECTRONIC CIRCUITS


If gas and electrical power are being supplied to the fryer, the next most likely cause of ignition
failure is a problem in the 24 VAC circuit. Verify that the drain valve is fully closed. The valve is
attached to a microswitch that must be closed for power to reach the gas valve (often, although the