Troubleshooting – FMI ES401 User Manual

Page 13

Advertising
background image

www.fmiproducts.com

122638-01E

13

TRoUbLEShooTINg

WARNING: Turn off appliance and let cool before servicing. Only

a qualified service person should service and repair heater.

POSSIBLE CAUSE

REMEDY

OBSERVED PROBLEM

1. Fireplace has overheated

and safety devise has

cause thermal switch to

disconnect or home circuit

breaker has opened

1. Loose wiring

2. Flame motor defective

1. Wiring is loose

1. Wiring is loose

1. Flame motor is defective

2. Flame generation contacts

dirty/obstructed

1. Low batteries

2. Not aiming control cor-

rectly

3. Defective remote control

and/or sensor

1. Control failure

2. Breaker tripped
1. Thermal switch has been

tripped

2. Circuit breaker has been

tripped

3. Wiring is loose

4. Heater is defective

5. Thermostat cycled off

Fireplace turns off and will

not turn on

Flame is not moving

Flame is not visible

Log set and/or ember is not

glowing

Flame sputters/flashes

Remote control does not

work

Fireplace will not come on

when switch is flipped to ON

Heater does not provide heat

when turned on

1. Reset switch by turning

main power switch off and

waiting 5 minutes then turn-

ing it back on or reset circuit

breaker

1. Inspect wiring for loose

connections

2. Call a qualified service techni-

cian to replace flame motor

1. Disconnect from power

source and inspect wiring for

loose connections and repair

or replace if necessary

1. Disconnect from power

source and inspect wiring for

loose connections and repair

or replace if necessary

1. Call a qualified service techni-

cian to replace flame motor

2. Disconnect power. Fol-

low steps to replace flame

generation LED. Clean

contacts with dry cloth.

1. Replace AAA batteries in

remote control

2. Aim control at sensor lo-

cated directly behind glass

screen in center of unit just

above logs

3. Replace remote control

and/or sensor

1. Call a qualified service tech-

nician to replace control

2. Reset breaker
1. Turn unit off. Turn off power

to unit for 5 minutes. Turn

power and unit on.

2. Turn off circuit breaker that

supplies electricity to unit.

Wait 5 minutes then flip

circuit breaker back on

3. Disconnect from power

source and inspect wiring for

loose connections and repair

or replace if necessary

4. Replace heater

5. Change to higher setting

Advertising