Figure 8 - Fireplace Settings (Default

Settings are Circled)

CLEANINg ANd MAINTENANCE

WARNING: Always discon-

nect power and allow the heater

to cool before performing any

cleaning, maintenance or reloca-

tion of this heater. Turn controls

to OFF and remove plug from

outlet or turn off circuit breaker

to heater.

To service electric fireplace it may be neces-

sary to remove it from the mantel or enclosure

in which it is installed. Let unit cool completely

before cleaning or servicing.

CLEANING FIREBOx

1. Open control panel door by pressing on

right side. A spring magnet will push door

forward. Pull door down to open.

2. Remove 2 screws holding front trim in

place. Pull gently to remove trim (see

Figure 9). There are magnets on the lower

portion of trim (see Figure 9)

3. With gloves and safety glasses in place,

remove 4 screws from glass retainer

brackets (see Figure 9).

4. Carefully remove front glass and brackets

(see Figure 10).

5. Using a brush vacuum attachment, gently

clean compartment.

6. After cleaning compartment, replace front

glass, brackets and trim.

Figure 10 - Removing Brackets and Front

Glass

Bracket

Front Glass

Figure 9 - Removing Trim

Magnets on

Back of Trim

Screws

Bracket

Trim

Control Panel Door

oPERATIoN

Continued

HEATER

Off Low Medium High

FLAME

Off Low Medium High

EMBER

Off Low Medium High

BACKLIGHT Off Low

High

Figure 7 - Remote Control For Electric

Fireplace

Glass Bracket

Screws

3. When using remote control, aim remote

at sensor located in center of unit just

above log set. IMPORTANT: This remote

control must remain within 20 feet (6 m)

of fireplace to be effective.

4. When power switch is turned off, fireplace

settings go back to default (see Figure 8).