7

Tools and building supplies required for

installation:
• Saw

• Square

• Pliers

• Gloves

• Hammer

• Level

• Phillips screwdriver

• Surround

• Framing materials

• Electric drill/bits

• Tape measure

• Wall-finishing materials

• Caulking material

INSTALLATIoN

Continued

Heater

Flame

Ember

Backlight

Power

Figure 6 - Controls For Electric Fireplace

Lighted Power Switch

Ember

Control

Heater

Control

Flame

Control

FINIShINg

WARNING: Control panel

door on this heater cannot, in

any way, be covered as it may

create a fire hazard.

Combustible Finishing Material: Materials

made of or surfaced with wood, compressed

paper, plant fibers, plastics or any material

capable of igniting and burning, whether flame

proofed or not, plastered or unplastered (this

includes drywall).
Noncombustible Finishing Material : Ma-

terials which will not ignite and burn. Such

materials are those consisting entirely of

steel, iron, brick, tile, concrete, slate, glass

or plasters or combinations thereof or have a

fire rating of zero.

FINISHING CHECKLIST

• Power supply service must be completed

prior to finishing to avoid reconstruction.

• Grills and air openings cannot be covered

in any circumstances.

Note: The heater is a zero clearance fireplace

and may be finished with combustible or non-

combustible finishing materials.
When using paint or lacquer to finish the

mantel, they must be heat resistant to prevent

discoloration.

Backlight

Control

CAUTION: Provide adequate

clearances around the air open-

ings and adequate accessibility

clearances for servicing and

proper operations.

Installing as Insert

Once the site has been prepared, your fire-

place insert can be installed.

1. Make sure power switch is in the OFF

position.

2. Push fireplace insert so trim is against

finished mantle or wall surface.

oPERATIoN

The controls (see Figure 6) are located behind

hinged control panel door. If using heater, con-

trol panel door will be hot during and immedi-

ately after operation. Open door by pressing

on right side. A spring magnet will push door

forward. Pull door down to open.
1. Connect fireplace to power source. Turn

on lighted power switch (see Figure 6).

2. Adjust Flame/Ember/Backlight/Heater

to desired settings using the control pad

on fireplace (Figure 6) or remote control

(Figure 7, page 8). Figure 8, page 8,

shows fireplace settings available. Default

settings are circled. Press control pad or

remote control buttons once and release

to adjust settings.

Note: When on, ember bed will lighten

and darken automatically to simulate real

embers.

The heater is pre-set to the following

temperatures:

HIGH will shut off when room reaches

approximately 86° F (30° C).

MEDIUM will shut off when room reaches

approximately 79° F (26° C).

LOW will shut off when room reaches

approximately 72°F (22° C).

Note: Fan on heater will continue to run for 5-7

seconds after heater has been turned off.