Locating fireplace, Installation – FMI ES401 User Manual

Page 5

Advertising
background image

www.fmiproducts.com

122638-01E

5

Figure 3 - Heater Locations

CAUTION: Do not expose the

heater to the elements (such as

rain, etc.)

CAUTION: Wear gloves and

safety glasses for protection

during installation and main-

tenance.

This electric fireplace can be installed in a

mantel, framed into a wall or installed into an

existing fireplace. If installing into a mantel,

follow mantel’s assembly instructions.

LoCATINg FIREPLACE

Continued

Figure 3 illustrates a variety of ways the heater

may be located in a room. The heater may

be installed directly on the floor or raised on

a hearth.

INSTALLATIoN

WARNING - RISK OF FIRE!

The power cord must not be

pinched or against a sharp edge.

Secure cord to avoid tripping or

snagging to reduce the risk of fire,

electric shock or personal injury.

Do not run cord under carpeting.

Do not cover cord with throw rugs,

runners or the like. Arrange cord

away from traffic areas and where

it will not be tripped over.

WARNING - RISK OF FIRE!

To prevent a possible fire, do

not block air intake or exhaust

in any manner. Do not use on

soft surfaces where openings

may become blocked.

WARNING - RISK OF FIRE!

Do not blow or place insulation

against the firebox.

WARNING: If the informa-

tion in these instructions is

not followed exactly, a fire or

explosion may result causing

property damage, personal in-

jury or death.

Do not store or use gasoline or

other flammable vapors in the vi-

cinity of this or any other heater.

INSTALLING FIREPLACE

Select a suitable location that is not suscep-

tible to moisture and is a safe distance from

drapes, furniture and high traffic areas.
Note: Follow all national and local electrical

codes. This insert can be installed into either

an existing fireplace or as new construction/

renovation.
Installing in Mantel

1. Assemble mantel according to mantel

instructions.

2. Locate mantel near a wall (or corner

depending on mantel type) close to a

power source. You may have to alter base

boards to fit mantel flush against wall.

3. Connect fireplace to power source. Insert

fireplace into front of mantel. Be careful not

to scratch finish on base. Fireplace will fit

flush against front of mantel.

4. Push mantel with fireplace into final location.
Existing Fireplace Installation

1. Thoroughly clean out existing fireplace

and hearth area.

2. Seal all drafts, vents or ash clean-outs

with fiberglass insulation. Seal flue. Once

sealed, close damper to stop debris from

falling onto unit.

3. If existing fire box is susceptible to mois-

ture, cap top of chimney flue to prevent

infiltration of water.

Corner Mantel

Installation

Wall Mantel

Installation

Framed

Into Wall

or Existing

Fireplace