Lens Connector

Auto-iris Lens

2

1

4

3

AUTO-IRIS LENS

Connector
Pin No.

1

2

3

4

(1) VIDEO SIGNAL

CONTROL

+9 VDC (40 mA max.)

+9 VDC (40 mA max.)

AI-VIDEO

GND

(2) DC VOLTAGE

DRIVE

CONT. (–)

CONT. (+)

DRIVE (+)

DRIVE (–)

(View from wiring side of plug)

Fig. 2

Table 1

A. ELECTRICAL CONNECTIONS

Table 1 shows two different wiring schemes
for the 4pin Auto-iris connector.
If a “Standard” auto-iris is to be used, see “(1)
VIDEO SIGNAL CONTROL”. (Table 1)
For DC controlled iris, use “(2) DC VOLTAGE
DRIVE”.

CAUTION:

The output power for auto-iris lens is +9 VDC and the
maximum current capacity is 40 mA.
When using an auto-iris lens requiring voltage and
current other than specified, supply lens power only
from an external power supply.
Set the Esc switch (#2 switch of Dip Switch) to “OFF“
when using an auto-iris lens type.