4 response to diagnostic command – FUJITSU MPC3065AH User Manual

Page 164

Advertising
background image

C141-E056-01EN

6 - 5

6.1.4

Response to diagnostic command

When the master device receives an EXECUTE DEVICE DIAGNOSTIC command and the
slave device is present, the master device checks the PDIAG- signal for up to 6 seconds to see
if the slave device has completed the self-diagnosis successfully.

The master device does not check the DASP- signal.

After the slave device receives the EXECUTE DEVICE DIAGNOSTIC command, it shall
report the result of the self-diagnostics to the master device as described below:

PDIAG- signal: negated within 1 ms and asserted within 5 seconds then negated within 6

seconds.

When the IDD is set to a slave device, the IDD asserts the DASP- signal when negating the
PDIAG- signal, and negates the DASP- signal when asserting the PDIAG- signal.

Max. 6 sec.

Max. 5 sec.

Max. 1 ms.

If the slave device is preset, DASP- signal is checked for up to
6 seconds.

DASP-

PDIAG-

BSY bit

X'1F7' Reg.
Write

Status Reg.
BSY bit

Slave device

Master device

Figure 6.4

Response to diagnostic command