2 logical address – FUJITSU MPC3065AH User Manual

Page 166

Advertising
background image

C141-E056-01EN

6 - 7

6.2.2

Logical address

(1)

CHS mode

Logical address assignment starts from physical cylinder (PC) 0, physical head (PH) 0, and
physical sector (PS) 1 and is assigned by calculating the number of sectors per track which is
specified by the INITIALIZE DEVICE PARAMETERS command. The head address is
advanced at the subsequent sector from the last sector of the current physical head address.
The first physical sector of the subsequent physical sector is the consecutive logical sector
from the last sector of the current physical sector.

Figure 6.5 shows an example (assuming there is no track skew).

LS

63

LH2

LH1

LH0

LS

2

LS

1

LS

1

243

242

241

190

189

64

63

62

3

2

12

11

1

1

127

126

Physical sector

Physical sector

ex: Zone 0

Physical parameter
- Physical sector: 1 to 241 (For the rest, 2 spare sectors)
Specification of INITIALIZE DEVICE PARAMETERS command
- Logical head: LH=0 to 14
- Logical sector: LS=1 to 63

Physical cylinder 0

Physical head 1

Physical cylinder 0

Physical head 0

LS

63

LS

1

LS

63

LS

1

SP

SP

LS

52

. .

. .

. .

. .

. .

. .

. .

. .

LH3

LS

63

LS

53

LS

1

LS

63

LS

1

LS

63

LS

1

LS

1

SP

SP

LS

63

. .

. .

. .

. .

. .

. .

. .

. .

. . . .

. . . .

. . . .

LH4

LH3

LH5

LH6

LH7

75

138

137

74

201

200

243

242

Figure 6.5

Address translation (example in CHS mode)

Advertising