2 command descriptions – FUJITSU MPC3065AH User Manual

Page 79

Advertising
background image

C141-E056-02EN

5 - 16

5.3.2

Command descriptions

The contents of the I/O registers to be necessary for issuing a command and the example
indication of the I/O registers at command completion are shown as following in this
subsection.

Example: READ SECTOR(S)

At command issuance (I/O registers setting contents)

Bit

7

6

5

4

3

2

1

0

1F7

H

(CM)

0

0

1

0

0

0

0

0

1F6

H

(DH)

×

L

×

DV

Head No. / LBA [MSB]

1F5

H

(CH)

Start cylinder address [MSB]

/ LBA

1F4

H

(CL)

Start cylinder address [LSB] / LBA

1F3

H

(SN)

Start sector No.

/ LBA [LSB]

1F2

H

(SC)

Transfer sector count

1F1

H

(FR)

xx

At command completion (I/O registers contents to be read)

Bit

7

6

5

4

3

2

1

0

1F7

H

(ST)

Status information

1F6

H

(DH)

×

L

×

DV

End Head No. / LBA [MSB]

1F5

H

(CH)

End cylinder address [MSB] / LBA

1F4

H

(CL)

End cylinder address [LSB] / LBA

1F3

H

(SN)

End sector No.

/ LBA [LSB]

1F2

H

(SC)

X‘00’

1F1

H

(ER)

Error information

CM: Command register

FR: Features register

DH: Device/Head register

ST: Status register

CH: Cylinder High register

ER: Error register

CL: Cylinder Low register

L: LBA (logical block address) setting bit

SN: Sector Number register

DV: Device address. bit

SC: Sector Count register

x, xx: Do not care (no necessary to set)

Advertising
This manual is related to the following products: