5.6 Hose and Wand Operation (cont.)

5. The oil will start to flow immediately into the

frypot. Keep the wand inside the frypot at
all times while the filter pump is activated.

6. Rinse debris from the frypot into the filter

pan with the wand.

7. When cleanup is complete, press the

wand/disposal switch to OFF, close the drain
valve (red handle) and close the
wand/disposal valve with the blue handle.


8. Disconnect the hose/wand from the fryer.
9. Lift the quick-disconnect end of the

hose/wand and drain excess oil into the
frypot.

10. Store the hose/wand in its designated

location.






5.7 Complete Filtering

1. Refill the frypot by rotating the yellow handle

to open the oil-return valve and activate the
filter pump.



2. After the frypot refills, allow the oil to bubble

for 10-15 seconds to ensure evacuation of all
oil from the oil return lines. Rotate the
yellow handle to close the oil-return valve
and stop the filter pump. Filtration is
complete. Filter another frypot or return the
fryer to operation.






The red handle is attached to the drain valve. The
yellow handle is attached to the oil return valve.