Frymaster SINBAD II User Manual

Page 13

Advertising
background image

3-2

PROBLEM

Probable Causes

Corrective Action

A.

ON/OFF rocker switch is in OFF
position.

A.

Place rocker switch in the ON
position.

B.

Unit is not plugged in.

B.

Plug unit in.

C.

Main circuit breaker is tripped.

C.

Reset circuit breaker.

UNIT WILL NOT

POWER UP or

NOTHING HAPPENS

WHEN “RUN” MODE

IS SELECTED. If the problem is not corrected by one of the above actions, call FASC.

A.

Dispensing chute is not properly
positioned on the load cell arms.

A.

Reposition dispensing chute so that
is firmly seated on the load cell
arms. Turn the unit OFF then back
ON using the ON/OFF rocker
switch. Press the RUN switch

RUN SWITCH

INDICATOR AND

PROGRAM SWITCH

INDICATOR ARE

FLASHING. Simultaneous flashing of the run switch indicator and program switch indicator

signals that the unit is not properly zeroed. If the problem is not corrected by the
above action, call FASC.

A.

Dispensing chute is full.

A.

If the dispense chute has been
loaded but not dispensed, nothing
will happen until the batch has been
dispensed, except when the batch
weight is increased. Insert a basket
into the dispensing well to dispense
batch.

B.

Unit is not in RUN mode.

B.

Press RUN switch once.

NOTHING HAPPENS

WHEN A BATCH

SIZE SELECTOR IS

PRESSED.

If one of the above actions did not correct the problem, call FASC.

A.

The load cell may not have been
satisfied within 30 seconds, normally
because the hopper is empty or the
fries have “bridged”.

A.

Check the hopper to verify that the
deflector is properly positioned. If
there are fries in the hopper, verify
that there is no bridging. If the
hopper is empty, reload the hopper.
Press the PROGRAM switch once
to place the unit back into opera-
tion.

DISPENSE DOOR

DOES NOT OPEN

WHEN BASKET IS

INSERTED.

If the above action did not correct the problem, call FASC.

A.

If the erratic batch weights are
occurring only occasionally, the
probable cause is bumping, jarring,
and/or unusual vibration (such as
caused by inserting a basket with
undue force, the slamming of a freezer
door, or the passing of a nearby train).

A.

Exercise care when working around
the unit to avoid bumping or jarring
it while it is in operation. Ensuring
that the unit is not touching
adjacent walls, and placing the unit
on a rubber mat will reduce the
effect of environmental vibrations.

ERRATIC BATCH

WEIGHTS ARE

BEING DISPENSED.

B.

If the erratic batch weights are
occurring consistently, the probable
causes are misaligned components
(B1) or improperly programmed batch
weights (B2).

B1.

Verify that the dispensing chute is
properly positioned on the load cell
arms, that the deflector is properly
positioned in the hopper, and that
the hopper is fully seated behind
the locking rim on the cradle
assembly.