2. WIRING

2.1 Standard

Wiring

All wirings are terminated at the rear of the processor unit.

CAUTION

The processor unit and power
supply unit are shipped with
15 A fuse.

Replace fuse with 7 A or 3 A
depending on input voltage as
below.

Attach appropriate label
(supplied) to the fuse cover on
the power cable.
Use of wrong fuse can result
in damage to the equipment.

POWER

DATA 3

NETWORK

CONT

DATA 1

DATA 2

DJ-1

REMOTE FMD DISPLAY

RGB OUT

NTSC/PAL

2

GND

3

INPUT

12-24 VDC

1

CARD SLOT

3

2

1

GND

F.G.

12 VDC

OUTPUT

OPTION

Processor Unit RPU-014

GPS Receiver
GP-310B/320B

Plotter

Heading Sensor
PG-1000/500
AD-100

Control Unit
RCU-017

Network
Equipment

CCD
Camera

VGA
MONITOR

Sub-display

Power Supply
Unit

(M1953C-BB)

External
Buzzer

12-24 VDC

MJ-A3SPF0018-050Z (5 m)

: Standard supply
: Optional supply
: Local supply

ground
IV-2sq

MJ-A6SPF0014-xxx

MJ-A7SPF0006-050 (5 m)

MJ-A6SPF0007-100 (10 m)
MJ-A6SPF0003-050 (5 m)
MJ-A6SPF0009-100 (10 m)

MJ-A6SPF0012-100 (10 m)
MJ-A6SPF0012-050 (5 m)
MJ-A6SPF0009-100 (10 m)

MJ-B24LPF
0010-xxx

XN12A-RSB-0072-060
XN12A-RSB-0073-060
XN13A-RSB-0072-060

XN12A-RSB-0070-059
XN12A-RSB-0073-059

XN10A-RSB-0070-064
XN10A-RSB-0073-064

RSB-0071-057

Antenna unit

RSB-0094-0075

MJ-B24LPF0002-xxx
(for M1823C-BB, M1833C-BB)
MJ-B24LPF0005-xxx
(for M1933C-BB, M1943C-BB

M1953C-BB)

10/15/20/30 m

Model

Input Voltage

M1823C-BB

7 A

3 A

12 VDC 24 VDC

7 A

3 A

M1833C-BB

15 A

7 A

M1933C-BB

15 A

7 A

M1943C-BB

3 A

3 A

M1953C-BB

15 A

7 A

Power supply unit

3COX-2P-6C
(5/10 m)

RW-8577 (5 m)

12-24 VDC

3 A

3 A

GD-1900C-BB

0.3 A MAX

Memory Card
Interface Unit CU-200

MJ-A6SPF/TM11AP8C 050/100
(5 m or 10 m)

MJ-A3SPF0026-050/100
(5 m or 10 m)

A

A