Frymaster FTB-350A User Manual

Page 12

Advertising
background image

12

F3000 TEST PROCEDURE FOR PITCO FRYERS (18WKS FULL, SG18
FULL, SSH75 FULL, SG6H FULL, 14WKS FULL, 7WKS FULL, 7-
2WKS SPLIT, E18WKS FULL, SE18 17 KW FULL and SE 22KW FULL)

Ensure the controller is set to PITCO using code 7628 in tech mode.
With the Controller displaying OFF press and hold the check button until PRODUCT
SETUP is displayed. Press the right arrow to tech mode. Enter 7628. Set LOCALE to
NON-CE. Press the right arrow. Set system type to PITCO. Press the right arrow. Set
ENERGY to ELEC or GAS. Press the right arrow. Set TYPE to fryer type desired. Press the
right arrow. Set FRESH OIL to NONE. Press the right arrow. Set WASTE OIL to NONE.
Press the right arrow. Press the check button at EXIT.

A.

INITIAL TEST SET-UP
See page 6 for instructions to run initial test set-up.

B.

TEST POWER TO FRYER INTERFACE BOARD
See page 6 for instructions to test power to fryer interface board.

C.

TEST MELT-CYCLE FUNCTION
See page 6 for instructions to test melt-cycle function.

D.

TEST CONTROLLING FUNCTION
See page 7 for instructions to test controlling function.

E.

TEST CONTROLLER HIGH LIMIT
See page 7 for instructions to test controller high limit.

F.

TEST PROBE FAILURE MALFUNCTION
See page 7 for instructions to test probe failure malfunction.


Controller test is now complete.

Advertising