F3000 TEST PROCEDURE FOR HENNY PENNY PRESSURE FRYERS
(HP580 and HP590)

Ensure the controller is set to HENNY PENNY 580/590/290 FULL using code 7628 in tech
mode.
Press and hold the check button until PRODUCT SETUP is displayed. Press the right arrow
to tech mode. Enter 7628. Set LOCALE to NON-CE. Press the right arrow. Set system type
to HENNY PENNY. Press the right arrow. Set ENERGY to ELEC. Press the right arrow.
Set TYPE to HP580/590. Press the right arrow. Set FRESH OIL to NONE. Press the right
arrow. Set WASTE OIL to NONE. Press the right arrow. Press the check button at EXIT.

A.

INITIAL TEST SET-UP
See page 6 for instructions to run initial test set-up.

B.

TEST POWER TO FRYER INTERFACE BOARD
See page 6 for instructions to test power to fryer interface board.

C.

TEST MELT-CYCLE FUNCTION
See page 6 for instructions to test melt-cycle function.

D.

TEST CONTROLLING FUNCTION
See page 7 for instructions to test controlling function.

G.

TEST CONTROLLER HIGH LIMIT
See page 7 for instructions to test controller high limit.

H.

TEST PROBE FAILURE MALFUNCTION
See page 7 for instructions to test probe failure malfunction.

I.

TEST PRESSURE SOLENOID ACTIVATION
1. Ensure controller is set to OFF.
2. Set up a product opening and closing pressure solenoids.

a) Press and hold the check button until PRODUCT SETUP is displayed.
b) Press the check (

9) button.

c) Enter 3228
d) Select and press a button that is not illuminated.
e) Enter TEST as LONG NAME (using the down arrow to scroll to next

letter). Press the right (

X) arrow.

f) Enter TEST as SHORT NAME (using the down arrow to scroll to next

letter). Press the right (

X) arrow.

g) Ensure COOKING MODE is set to MULTIPLE SETPOINT. If not press

the down (

T) arrow. Press the right (X) arrow.

h) Enter 1:00 at 1 TIME. Press the right (

X) arrow.

i) Leave 1 TEMPR at setpoint of 340°F/171°C. Press the right (

X)

arrow.

j) Leave 1 FLEX at 0. Press the right (

X) arrow.

k) Set 1 PRESSURE SOLENOID to CLOSE. Press the right (

X) arrow.

l) Enter 00:30 at 2 TIME. Press the right (

X) arrow.

m) Leave 2 TEMPR at setpoint of 340°F/171°C. Press the right (

X)

arrow.

Advertising