Frymaster FTB-350A User Manual

Page 9

Advertising
background image

9

n) Leave 2 FLEX at 0. Press the right (

X) arrow.

o) Leave 2 PRESSURE SOLENOID to OPEN. Press the right (

X) arrow.

p) Leave :00 at 3 TIME. Press the right (

X) arrow.

q) Leave 1 ALARM TIME at :00. Press the right (

X) arrow.

r) Leave AFTER COOKING to COOL. Press the right (

X) arrow.

s) Leave FILTER LOCKOUT to 0. Press the right (

X) arrow.

t) Leave QUANTITY? to NO. Press the right (

X) arrow.

u) Leave HEAD COUNT to .0. Press the right (

X) arrow.

v) Leave INSTANT ON to 0. Press the right (

X) arrow.

w) Press check (

9) button at EXIT.

x) Press the SCAN button two times to OFF.

3.

Press controller ON/OFF switch to ON (set point = 340°F/171°C).

4.

Press the product button programmed in step 2 to start a cook.

5.

The PRESSURE SOLENOID indicator (5) illuminates. After 30 seconds
the pressure SOLENOID indicator (5) turns off.

6.

Press the product button with blinking LED when DONE is displayed.

7.

Controller test is now complete.

F3000 TEST PROCEDURE FOR HENNY PENNY PRESSURE FRYERS
(HP690)

Ensure the controller is set to HENNY PENNY 690/390 FULL using code 7628 in tech
mode.
Press and hold the check button until PRODUCT SETUP is displayed. Press the right arrow
to tech mode. Enter 7628. Set LOCALE to NON-CE. Press the right arrow. Set system type
to HENNY PENNY. Press the right arrow. Set ENERGY to GAS. Press the right arrow.
Set TYPE to HP690/390 FULL. Press the right arrow. Set FRESH OIL to NONE. Press the
right arrow. Set WASTE OIL to NONE. Press the right arrow. Press the check button at
EXIT.

A.

INITIAL TEST SET-UP

1.

Set-up FTB-350A as follows:
(a) Set POWER switch (10) to OFF.
(b) Set PROBE switch (7) to Variable.
(c) Connect 120/24V transformer to 120VAC outlet or 240/24V

transformer to 240VAC outlet.

2.

Set controller up as follows:
(a) Set POWER switch to OFF.
(b) Connect FTB-350A 16-pin connector to rear of controller.
(c) Plug 4-pin drain switch into connector.
(d) Switch the HP690 POWER switch (11) to ON.
(e) Switch the HP690 ALARM switch (12) to OFF.

3.

Set FTB-350A POWER switch (10) to ON
(a) Program the set point to 340°F/171°C.