7 calibrating thermostat control (cont.), 8 replacing fryer components – Frymaster FMCFE User Manual

Page 14

Advertising
background image

MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-9

1.7 Calibrating Thermostat Control (cont.)

13. Close the fryer control panel and replace the screws in the upper corners.

14. Reinstall the thermostat knob with its pointer aligned with the 325°F (163°C) index mark on the

temperature dial.

15. Reconnect the fryer to the electrical power supply.

1.8 Replacing Fryer Components

1.8.1 Replacing Computer

1. Disconnect the fryer from the electrical

supply.

2. The controller bezel is held in place by

tabs at the top and bottom. Slide the
bezel up to disengage the lower tabs.
Then slide the bezel down to disengage
the upper tabs.

3. Remove the two screws in the upper

corners of the control panel and swing
the panel open from the top, allowing it
to rest on its hinge tabs.

4. Disconnect the wiring harness from the

back of the controller and, if replacing
the harness, disconnect it from the
interface board (arrows).

5. Disconnect the ground wire, and then

remove the controller by lifting it from
the hinge slots in the control panel
frame.

6. Ensure the new computer is properly

configured for the fryer on which it is
installed (i.e., gas or electric, full or
split pot and Celsius or Fahrenheit.
Although identical in appearance,
computers configured for use on one
type of fryer are not directly
interchangeable with those configured
for use on another type.

7. Reverse the procedure to install a new

controller or wiring harness.




If replacing harness, disconnect the harness from
the controller and interface board (arrows).

If replacing controller, disconnect the ground wire
and the 15-pin connector (arrows).