MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-33

1.10.2 Initial Troubleshooting, 24VAC Frying Systems

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Burner won’t ignite.

Light in ON/OFF switch

is not illuminated.

A. ON/OFF switch is off.

A. Turn ON/OFF switch on.

ON/OFF switch is on,

but the switch light is

not illuminated.

A. No 24 VAC output from transformer.

A. Check 24VAC circuit. Replace

transformer if defective.

A. Drain microswitch circuit (filter-

equipped units) is open.

A. Ensure drain valve is fully closed and

microswitch is functioning. Replace
microswitch if defective.

B. 24VAC is present at ON/OFF switch,

but continuity of the switch in ON
position is not "0".

B. On/Off switch is defective. Replace

switch with a known working switch.

C. Continuity of thermostat is not "0"

(cooking oil/shortening temperature is
at least 15°F below thermostat
setting).

C. Thermostat is defective. Replace with

a known working thermostat.

ON/OFF switch is on

and the switch light is

illuminated, but there is

no output to gas valve.

D. Gas valve is suspect.

D. Go to "No burner flame".

A. Pilot does not stay lit (fryer is on and

thermopile output is approximately
400 millivolts.

A. Check high-limit switch. Switch

continuity should be "0". If not, high-
limit switch is defective. Replace high-
limit switch.

B. Pilot does not stay lit (fryer is on and

thermopile output is not
approximately 400 millivolts.

B. Inspect thermopile (units without

interface board) and replace if
defective.

C. Pilot stays lit, and the high-limit and

thermopile are known working, but
burners fail to light.

C. Inspect gas valve and replace if

defective.

D. Gas valve is known to be good, but

there is not 24 VAC at the gas valve
terminals.

D. Inspect thermostat body (while still in

frypot) for damage. Remove and
replace thermostat if bent, dented or
cracked. Inspect leads for fraying,
burning, breaks and/or kinks. If found,
remove and replace thermostat.
Remove leads from terminal block,
allow oil to cool 15°F below thermostat
setting and check continuity. If
continuity is not "0", then thermostat
has failed. Replace thermostat.

No burner flame.

E. Continuity from terminal block to gas

valve thermostat wire is not "0".

E. Inspect wiring for breaks or shorts and

repair if necessary.