Installation – FMI VCM-36Q User Manual

Page 12

Advertising
background image

www.fmiproducts.com

122275-01G

12

NOTIcE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• raise the mantel to an accept-

able height

• remove the mantel

bUILT-IN FIREbOx INSTALLATION

Built-in installation of this firebox involves

installing firebox into a framed-in enclosure.

This makes the front of firebox flush with wall.

If installing a mantel above the firebox, you

must follow the clearances shown in Figure

7, page 11. Follow these instructions to install

the firebox in this manner.
1. Frame in rough opening. The firebox fram-

ing should be constructed of 2 x 4 lumber

or heavier. Use dimensions and rough

opening layout in Figure 8. Adjust framing

so that firebox flushes with finished wall

surface. If installing in a corner, use dimen-

sions in Figure 9, for rough opening.

2. Install gas piping to firebox location. See

Installing Gas Line on page 14 and Con-

necting to Gas Supply in log set owner’s

manual.

3. Carefully set firebox in front of rough

opening with back of firebox inside wall

opening.

4. Carefully insert firebox into rough opening.
5. Attach firebox to wall studs using nails

or wood screws through holes in nailing

flange (see Figure 10).

6. Install and properly test gas log heater.

Follow installation instructions included

with the vent-free gas log heater that is

being installed.

IMPORTANT: When finishing your firebox,

combustible materials such as wall board,

gypsum board, sheet rock, drywall, plywood,

etc. may be butted up next to the sides and top

of the firebox. Combustible materials should

never overlap the firebox front facing.

WARNING: Do not allow any

combustible materials to overlap

the firebox front facing.

IMPORTANT: Noncombustible materials such

as brick, tile, etc. may overlap the front fac-

ing, but should never cover any necessary

openings.

WARNING: Do not allow non-

combustible materials to cover

any necessary openings.

INsTAllATIoN

Continued

Figure 10 - Attaching Firebox to Wall

Studs

Figure 8 - Framing Dimensions

71" (50" Models)

100" (50" Models)

65" (42" Models)

92" (42" Models)

86.5" (36" Models)

61" (36" Models)

Maintain 1

1

/

2

"

Clearance at Sides

and Back of Fireplace

1

1

/

2

" Clearance

Not Required at

Nailing Flanges

Figure 9 - Corner Installation

30.125"

59.375" (50" Models)

54.625"

51.375" (42" Models)

45.375" (36" Models)

28.250"

(36" Models)

Nailing

Flanges

Nails or

Wood

Screws