State of Massachusetts: The installation

must be made by a licensed plumber

or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural

gas-fired supplemental room heaters

shall provide to each purchaser a copy of

527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for

bedroom and bathroom installation in

the Commonwealth of Massachusetts.

ProdUCT FeATUres

OpERATION

This firebox is designed for use with approved

ANSI Z21.11.2 decorative type unvented room

heaters. (Physical size limitations apply. Refer

to minimum firebox requirements supplied

with log heater.) It requires no outside vent-

ing or chimney making installation easy and

inexpensive.

loCAl Codes

loCATINg FIreBoX

pLANNING

Plan where you will install the firebox. This will

save time and money later when you install

the firebox. Before installation, consider the

following:
1. Where firebox will be located. Allow for

wall and ceiling clearances (see Installa-

tion Clearances, page 11).

2. Everything needed to complete installation.
3. These models CANNOT be installed in

a bedroom unless maximum Btu rating

of installed vent-free log set is less than

10,000 Btu/hr.

4. Proper air for combustion and ventilation

(page 8).

Install and use firebox with care. Follow all

local codes. In the absence of local codes,

use the latest edition of The National Fuel Gas

Code ANSI Z223.1/NFPA 54*. Firebox must

be electrically grounded in accordance with

the National Electrical Code, ANSI/NFPA70

(latest edition).