Cabinet troubleshooting – Frymaster 8196606 User Manual

Page 17

Advertising
background image

Cabinet Troubleshooting

3-1

The master control display and the row displays show error messages when there is a problem. The
messages are shown in the matrix below along with possible causes and diagnostic tests.








Error Message

Cause

Tests

Call service row display
error 

Row number also displayed *

 

The master control board has lost 
communication with the specified 
board. 

Turn the cabinet off and back on. 

Ensure there are no software 
incompatibilities. 

Inspect ribbon cable connections. 


Call service distribution
board 0 error*

The master control board has lost 
communication with the top 
distribution board. 
 
 

A display connection can produce 
this display. Before replacing a 
distribution board, remove power 
from the unit and disconnect the 
displays from the affected 
distribution board. Return power 
to the unit and, one at a time, plug 
in the displays, cycling power each 
time. If the problem is display‐
related it will go away with the 
affected display disconnected. 

Call service distribution
board 1 error*  

The master control board has lost 
communication with the bottom 
distribution board. 

 

Call service rate of
rise top**

Row’s top plate failed to reach 
required temperature in prescribed 
time window after startup or when 
switching between menus. 

Turn the cabinet off and on, which 
can clear the problem if it is 
software related.  

Check top plate RTD output against 
chart on page 2‐4. 

Enter service code (see page 2‐1) 
and switch top plate on and off to 
ensure it is responding to cabinet 
circuits. 

Call service rate of
rise bot **

Row’s bottom plate failed to reach 
required temperature in prescribed 
time window after startup or when 
switching between menus. 

Turn the cabinet off and on, which 
can clear the problem if it is 
software related.  

Check bottom plate RTD output 
against chart on page 2‐4. 

Enter service code (see page 2‐1) 
and switch bottom plate on and off 
to ensure it is responding to 
cabinet circuits. 

Call service top row temp
too high **

RTD sensor is producing a reading 
that is out of range. The problem can 
be a failed RTD, heater or 
distribution board. 

Compare plate temperature to 
displayed temperature.  

Compare plate RTD resistance to 
chart on page 2‐4. 

Switch plate on/off with service 
code to ensure it is responding to 
cabinet circuits. 

With plate on and calling for heat, 
check amp draw on leads between 
distribution board and heater 
plate. Amp draw on a properly 
functioning plate should be 1.67.

 

Call service bot row temp
too high**
Call service top row temp
too cool**
Call service bot row temp
too cool **
Call service top sensor
error hi temp** 
Call service bot sensor
error hi temp** 
Call service top sensor
error low temp **
Call service bot sensor
error low temp**
* Shown on master control display.  ** Shown on affected row display. 

Advertising