Cabinet Troubleshooting

3-1

The master control display and the row displays show error messages when there is a problem. The
messages are shown in the matrix below along with possible causes and diagnostic tests.








Error Message

Cause

Tests

Call service row display
error 

Row number also displayed *

 

The master control board has lost 
communication with the specified 
board. 

•

Turn the cabinet off and back on. 

•

Ensure there are no software 
incompatibilities. 

•

Inspect ribbon cable connections. 


Call service distribution
board 0 error*

The master control board has lost 
communication with the top 
distribution board. 
 
 

•

A display connection can produce 
this display. Before replacing a 
distribution board, remove power 
from the unit and disconnect the 
displays from the affected 
distribution board. Return power 
to the unit and, one at a time, plug 
in the displays, cycling power each 
time. If the problem is display‐
related it will go away with the 
affected display disconnected. 

Call service distribution
board 1 error*  

The master control board has lost 
communication with the bottom 
distribution board. 

 

Call service rate of
rise top**

Row’s top plate failed to reach 
required temperature in prescribed 
time window after startup or when 
switching between menus. 

•

Turn the cabinet off and on, which 
can clear the problem if it is 
software related.  

•

Check top plate RTD output against 
chart on page 2‐4. 

•

Enter service code (see page 2‐1) 
and switch top plate on and off to 
ensure it is responding to cabinet 
circuits. 

Call service rate of
rise bot **

Row’s bottom plate failed to reach 
required temperature in prescribed 
time window after startup or when 
switching between menus. 

•

Turn the cabinet off and on, which 
can clear the problem if it is 
software related.  

•

Check bottom plate RTD output 
against chart on page 2‐4. 

•

Enter service code (see page 2‐1) 
and switch bottom plate on and off 
to ensure it is responding to 
cabinet circuits. 

Call service top row temp
too high **

RTD sensor is producing a reading 
that is out of range. The problem can 
be a failed RTD, heater or 
distribution board. 

•

Compare plate temperature to 
displayed temperature.  

•

Compare plate RTD resistance to 
chart on page 2‐4. 

•

Switch plate on/off with service 
code to ensure it is responding to 
cabinet circuits. 

•

With plate on and calling for heat, 
check amp draw on leads between 
distribution board and heater 
plate. Amp draw on a properly 
functioning plate should be 1.67.

 

Call service bot row temp
too high**
Call service top row temp
too cool**
Call service bot row temp
too cool **
Call service top sensor
error hi temp** 
Call service bot sensor
error hi temp** 
Call service top sensor
error low temp **
Call service bot sensor
error low temp**
* Shown on master control display.  ** Shown on affected row display. 