Cabinet Troubleshooting

3-2

Failure modes not accompanied by a master control display are shown below with possible causes
and tests.

Symptom

Possible Causes

Tests


Unit fails to power
up; fans don’t run.

•

No power to cord.

•

Blown 20 amp fuse.

•

Circuit breaker open.

•

Check for line voltage at the switch
and the transformer.

•

Reset circuit breaker.

Unit powers up and
fans run; a display
fails to light.

•

Broken or improperly
seated ribbon cable.

•

Defective display.

•

Switch ribbon cable from functioning
display to failed component to isolate
problem.

Unit powers up and
fans run; all
displays fail to light.

•

Failed power supply.

•

Check for 5VDC at communication
board and distribution boards.

Rows heat
improperly or not at
all.

•

Improper wiring on
distribution board.

•

Defective distribution
board.

•

Defective heater.

•

Defective sensor.

•

Ensure heater leads and power inputs
on the distribution boards are properly
seated.

•

Test for 208VAC input on distribution
board and 208VAC output from heater
leads to heater plate when the unit is
calling for heat.

•

Switch power leads from properly
operating row to faulty row to isolate
problem.

•

Check resistance of RTD lead against
temperature chart. See Page 2-4.

•

Switch RTD lead from properly
operating row to faulty row to isolate
problem.

•

Test continuity of heater plate.