Test mode – Genicom PC4 User Manual

Page 41

Advertising
background image

EasyCoder PC4 User’s Guide

29

Chapter 3 — Operation

Test Mode

The Test Mode can be used for four main purposes:
• To adjust the Label Gap Sensor.
• To print a Test Label with a test pattern and a list of the printer's cur-

rent setup.

• To enter the Dump Mode.
• To reset the printer to its default settings.

Do not use continuous stock in the Test Mode. The printer

will not be able to detect any gaps and an error will occur.

Use the Test Mode this way:

1

After having loaded the printer with full width labels, tickets, or tags,

switch off the power to the printer.

2

Press and hold the Feed key while switching on the power.

3

Release the Feed key when the green indicator lamp flashes.

4

The printer will automatically adjust the label gap sensor and media

feed according to the characteristics of the media. The printer may

feed out 3-4 forms before the adjustment is completed. In case of

peel-off operation, remove the labels as they are fed out.

5

After a delay, a Test Label will be printed and the printer will be

placed in the Dump Mode (see Intermec Esim v6.XX, Programmer’s

Reference Manual).

6a

Tap the Feed key once to switch back to normal operation, or...

6b

...reset the printer to default setup values by pressing and holding the

Feed key for at least three seconds after the test label was printed. The

indicator lamp will switch to red to indicate that the printer was reset

to default setup. Restart the printer by switching off the power and

then switching it on again.

Refer to the Intermec ESim v6.XX, Programmer’s Reference Manual for

illustration and explanation of the test label.

Advertising