Servicing instructions, Servicing / fault finding charts, Ignition functional chec k 1 – Stovax PR0919 User Manual

Page 23: Servicing requirements

Advertising
background image

23

IGNITION

FUNCTIONAL

CHEC

k

1

PILOT

WILL

NOT

LIGHT

Ensure

there

is

no

debris

around

the

pilot

assembly,

(e.g.

soot,

etc.)

which

could

short

the

spark,

clean

the

area.

Operate

the

valve.

Is

there

a

spark?

Consult

User

Instructions

and

retry.

Check

alignment

of

pilot

burner

head,

change

the

ignition

lead.

See

Replacing

Parts,

section

2.

Check

isolation

tap

and

gas

meter,

retry.

Correct

and

retry.

Purge

the

gas

pipes

and

retry.

GO

TO

THE

NEXT

CHART

IGNITION

FUNCTIONAL

CHEC

k

2

SYSTEM

O

k

There

is

a

blockage

in

the

system,

check

the

inlet

test

point,

the

mag

seating

and

valve.

Check

thermocouple

leads

for

correct

orientation,

condition

and

connec

tion

Is

the

gas

turned

on

to

the

appliance?

Is

the

gas

pressure

correct?

Has

the

system

got

any

air

in

it?

Does

the

pilot

light?

Is

the

control

being

operated

correctly?

Will

the

pilot

light

with

a

match?

No

Yes

No

Yes

No

Yes

Yes

No

No

Yes

No

No

Yes

Yes

SERVICING INSTRUCTIONS

SERVICING / FAULT FINDING CHARTS

1. SERVICING REQUIREMENTS

This appliance must be serviced at least once a year by a

competent person.
All tests must be carried out in accordance with the current

CORGI recommendations.
1.1 Before any tests are undertaken on the appliance:

• Conduct a gas soundness test for the property to ensure

there are no gas leaks prior to starting work

1.2

• Fully check the operation of the appliance

Special checks

1.2.1 Clean any lint or fluff from the pilot - pay particular

attention to the aeration holes of the pilot

1.2.2 Clean away any fluff or lint from under the burner

1.2.3 Check the spark gap on the pilot is correct

• Correct any faults found during the initial tests

• Recommission the appliance conducting the usual safety

checks

1.3 Advise the customer of any remedial action taken.

REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY

FAULTS.

IF THE FIRE DOES NOT WORk, BUT HAS WORkED IN THE

PAST:

CHECK THE EMERGENCY SHUT OFF SWITCH

IN THE BOTTOM RIGHT CORNER BY THE DOOR IS

SWITCHED ON, SEE USER SECTION, PAGE 6

Symptom

Cause

Remedy

3 Short beeps from
control

Batteries low in
appliance

Replace appliance
batteries

No ignition, 5 second
continuous tone (there
may be several short
beeps before)

1. On/Off switch is in
OFF position
2. Loose/damaged
wire

1. Move switch to
ON position
2 Check interrupter
block and wires

No ignition, no tone,
motor turns slightly when
operated

Receiver board
damaged

Replace receiver

No pilot flame and
control continues to
spark

Thermocouple circuit
wired incorrectly

Correct wiring

Pilot lights, control

continues to spark, value

shuts down after 10 - 30

seconds

1. No spark at pilot

burner

2. Loose/damaged

wire

1. Rectify spark at

pilot burner

2. Check interrupter

and wires

Electronic Control Valve Fault Analysis

Advertising