SERVICING INSTRUCTIONS

REPLACING PARTS

13. MAIN INjECTOR

13.1 To change the main injector:

• Undo the injector fee pipe

• Undo the lock nut from the injector

• Replace with the correct size injector

14. PRIMARY AERATION PLATE

NOT ALL MODELS HAVE AERATION PLATES. REFER TO

NOTE AT BEGINNING OF INSTALLATION

INSTRUCTIONS.

14.1 Remove the burner module as described in Servicing

section 2.

14.2 Remove the fixing screw and slide the plate off the venturi.
14.3 Replace with the correct size plate and secure with the

screw. Ensure the lower edge of the plate is located over

the venturi flange. See diagram 20.

20

AR0766

15. CHANGING BETWEEN GAS TYPES

In order to change between gas types, it will be necessary to

change the following items:

Burner Unit

Pilot Injector

Control Valve

Injector

Aeration Plate (if required)

Data badge

A kit of parts is available for this, always quote the Model

number and Serial number when ordering any spare parts.

NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR

THE CORRECT GAS TYPE AND MODEL, A NEW UNIT

WILL NEED TO BE ORDERED WHEN CHANGING

BETWEEN GAS TYPES.

16. PRESSURE AND LEAk TESTING THE

APPLIANCE

16.1 Follow Section 7, Main Control Assembly, 7.1 and 7.2

• Access to the pressure test point can now be reached,

Diagram 21

21

AR1888

16.2 To leak test any gas joints on the appliance, the control

assembly must first be undone and tilted backwards, see

Section 7, 7.5 Diagram 13

16.3 Because there is now no burner fitted to perform a leak test,

place a manometer tube over the injector tip.

• Light the appliance and spray any joints with leak

detector fluid

• Tighten joints or replace as required