INSTALL FRAMING FOR HOOD
SUPPORT

IMPORTANT

Framing must be capable of

supporting 100 lbs.

If drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
Cut away enough drywall to expose 2 vertical studs

at the bracket location indicated on the template.

Install a horizontal support at least 1

x 6

between two wall studs at the bottom mounting
bracket installation location. The horizontal support
must be flush with the room side of the studs.
Use cleats behind both sides of the support to
secure to wall studs.

Reinstall drywall.

1

Centerline of
Installation
Space

8" Min. Opening for Ductwork

View From Rear

Cleats

1" x 6" Min.

Mounting

Support

Installation Instructions

Centerline of

installation

space

View from rear

cleats

1” x 6” min.

mounting

support

DUCTWORK, WIRING LOCATIONS

Determine the exact location of the vent hood.

Locate the template packed with the literature.

– Measure 36

″ from the floor to the top of the cooking

surface. Add hood installation height determined on
page 7. Mark that location.

– Use a level to draw a straight pencil line on the wall.

– Tape the template in position along the penciled

line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.

Ceiling ducting:
If ductwork will vent straight up to the ceiling:

Use a level to draw a line straight up, from the

centerline on the template to the ceiling.

Measure 5-1/2

from the back wall to the centerline

of an 8-1/2

hole on the ceiling.

NOTE: If drywall is not present, add drywall thickness
to the 5-1/2

dimension.

Wall Ducting:
If ductwork will vent to the rear:

Use a level to draw a line straight up from the

centerline on the template.

Measure at least 26

above the pencil line that

indicates the bottom installation height, to the
centerline of an 8-1/2

dia. duct hole. (Hole may

be elongated for duct elbow.)

HOUSE WIRING LOCATION:

The junction box is located on the top left side

of the hood.

Wiring should enter the back wall at least 22

above

the bottom of the hood, and within 6

of the left side

of the centerline.

5-1/2” centerline to wall

8-1/2” dia. hole

FOR CEILING VENT DUCTING

Centerline 26” above

the marked bottom

pencil line for

installation height.

FOR WALL VENT DUCT

INSTALLATION—VENTED TO THE OUTSIDE

Ceiling

8-1/2” min. opening for ductwork